ClearCanvas RIS/PACS v13.0 Cleome Edition Release Notes

Updated September 17, 2014

The following is a list of some known incompatibilities, defects and warnings that may affect use of the software. Where applicable, workarounds and guidance is provided. A note on versioning: because the various ClearCanvas projects share certain common libraries, version numbers are shared among various products such that common libraries have sequential versioning from release to release. Consequently, the products do not necessarily have sequential version numbers.  For the most up-to-date release notes for this version of the software, follow the link below.        

http://www.clearcanvas.ca/Portals/0/ClearCanvasFiles/Documentation/ReleaseNotes/13_0/Cleome

Change Log

Version

Changes

v.13

New Features/Improvements

  • ImageServer scalability has been improved by allowing instances to be clustered together so that higher study volumes can be processed in parallel
  • Webstation scalability has been improved to support more concurrent users
  • IntegrationServer now supports inbound HL7 2.5.1 ORM^O01 messages
  • ImageServer now supports the listing and searching of HL7 orders
  • A number of enhancements to the QC module have been made, including the addition of new statuses and report generation
  • The ClearCanvas RIS is now available with a Spanish UI
  • Study level auto-routing rules, and optionally auto-routing based on QC status

Notable Bug Fixes

  • 10424: All Shredhost services appear identical in Task Manager
  • 11343: Cannot abort closing Workstation if media writing in progress
  • 11526: Editing patient name in IS by changing caps only does not work
  • 11588: Primary study not loaded for linked procedures when go to next item selected
  • 11589: RIS report printing should support appropriate letterhead for multi facility sites
  • 11777: Cannot delete studies in the ImageServer using the Web GUI
  • 12183: RISServer cannot recover from httplistener error
  • 12298: RIS worklist search does not support names with accents
  • 12372: ImageServer date range validation removes the date entered by the user
  • 12373: ImageServer attempts compression on MR Spect non-images and fails
  • 12374: Calendar control in ImageServer study search page malfunctions after validation
  • 12399: Viewer freezes up when changing layout viewing a streamed study
  • 12404: Patient Name query against McKesson PACS doesn't work.  User should disable the AutoLeadingWildcard setting in the ClearCanvas.ImageViewer.Explorer.Dicom.DicomExplorerConfigurationSettings group.
  • 12488: RIS merge/unmerge orders can leave orders in a broken state. Important: Unmerge functionality has been removed to prevent orders from entering a broken state.  The workaround is to cancel the order and place the order again.
  • 12494: XML Rule editor window has malfunctioning scroll bars in Chrome
  • 12512: History and FilesystemQueue tab does not record compression performed on study

v.11

New Features/Improvements

  • ImageServer now supports inbound HL7 2.5.1 when used in conjunction with the new ClearCanvas IntegrationServer. Messages supported:
  • ADT^A40 (Patient Merge)
  • ADT^A08 (Patient Update)
  • ORU^R01 (Report Creation)
  • MIP and MinIP in both Workstation and Webstation DX
  • Slab MPR in both Workstation and Webstation DX
  • Breast Tomosynthesis storage and viewing in both Workstation and Webstation DX
  • Enhanced CT and MR viewing in both Workstation and Webstation DX
  • PDF report viewing in Webstation DX
  • Mobile image viewing (iOS, Android and Surface)
  • Editing and appending of key images on Workstation and Webstation DX
  • Reapplication of rules by ServerPartition in the ImageServer
  • Improved support for the ImageServer to server as a backup PACS including support for overwriting studies

Notable Bug Fixes

  • 6696: DICOM Editor save button appears to not save modified values
  • 7818: Out Of Memory error when workstation attempts to send really large images
  • 8033: Edits made in DICOM Editor are not seen in viewer if study was previously viewed in Study Filters
  • 10913: Forward slashes in HP/layout name cause missing protocol in Webstation
  • 10914: Forward slashes in HP/layout name cause weird menu nesting in Workstation
  • 11374: Incorrect time since study time reported in Easel
  • 11585: Adding a private tag column in Study Filters crashed the Workstation
  • 11593: Image with invalid DOB year will cause shredhost to fail
  • 11617: First click in Easel collapsed mode does not successfully select the series
  • 11619: Selecting series by Easel on webstation does not make image box active

v.10

Debut Cleome Release

  • WebstationDX - diagnostic quality images via HTML5 with clinical features including hanging protocols
  • Reformat and reslice - an in-place implementation of MPR
  • Ability to serve the HTML5 Webstation from a dedicated computer

Notable Bug Fixes

  • 8266: Large multi-frame images can now be written to media
  • 9336: Workstation no longer crashes when server and client clocks are out of sync
  • 10269: Memory management issues in cine and stacking
  • 10941: DICOM Print does not work with comma as the decimal symbol
  • 10943: Hanging protocols won't work if used and saved with different decimal symbols
  • 10946,10947: ImageServer rules processing may depend on server's decimal and digit grouping symbols

Other

  • "Administrative Services" has been renamed "EnterpriseServer" to match the component name

Known Incompatibilities

ID

Summary

Description

Component

792

Images don't display on grayscale monitors

The application does not support dynamic/static grayscale palettes on older Dome/Planar monitors/video cards. Images may appear blank or there may be rendering artifacts.  Thoroughly evaluate image quality with your display configuration to ensure that it is supported before deploying for clinical use.  Otherwise, newer display device(s) may be required.

Workstation

2920

Some controls appear black on some, usually older, Dome monitors

The application does not support all Dome monitors, particularly older models.  Thoroughly evaluate image quality with your display configuration to ensure that it is supported before deploying for clinical use.  Otherwise, newer display device(s) may be required.

Workstation

Configuration Warnings

ID

Summary

Description

Component

7173

Configure settings does not list local settings in Enterprise Mode

For the Team Edition of the Workstation, settings that are stored in the Local configuration file are not displayed in the Configure Settings component. With the Personal Edition, these settings are displayed.  The settings must be manually edited from the application configuration file found in the installation directory.

Workstation

8121

Exception generated on running workstation from network

The workstation should be installed only on the local machine.

Workstation

8449

DICOM related settings are not migrated on upgrade

Some settings are not being migrated as of yet on upgrade. These settings include those in the sections ClearCanvas.Dicom.Network.NetworkSettings, ClearCanvas.Dicom.ServiceModel.Streaming.StreamingSettings, and ClearCanvas.Dicom.DicomSettings.

Workstation

Known Bugs

ID

Summary

Description

Component

3914

Deleting log file while application is running causes strange behaviour

Only workaround is to stop the Workstation Shred Host Service, close the Workstation application, delete the log, then restart the service.

Workstation

4458

Streamed images displayed incorrectly when the server is compressing the images with JPEG Lossless

During compression of a study, the study may show up incorrectly in a Workstation client.

ImageServer

4881

Workstation considers a pixel to be in an ROI if the top-left corner is contained in the region.

Pixels are only considered to be in a region of interest if the top left corner is included in the region drawn - i.e. pixels on the top and left edge of the region may be unexpectedly excluded and pixels on the bottom and right edges may be unexpectedly included. If precision down to the pixel is required for mean, standard deviation and/or SUV, draw the ROI to include or exclude the top left corner of the desired pixels. The probe tool can be used to determine where the top-left corner of a pixel is.

Workstation

5750

MPR fails to render 8 bit volumes

No workaround, but such data sets are very rare.

Workstation

6590

Several pages are not displayed properly if the AE title contains spaces

The Device and WorkQueue pages do not display properly when there is a space in the AE Title.

ImageServer

6785

Opening study after display configuration change shows black workspace

If this problem occurs after changing monitor configuration, restart the application.

Workstation

7765

Study Integrity Queue Searching not consistent

Patient ID and Accession Number searches in the study Integrity Queue only search against the original study.  They do not search against the Conflicting Study.

ImageServer

7862

Does not render overlays from compressed images if overlay is embedded in pixel data

Images like this are not DICOM compliant.  Configure the modality to use the overlay repeating groups instead of embedding overlays in pixel data.

Workstation

8133

Reference lines are not captured in clipboard images

No workaround.

Workstation

8188

ImageServer UI can time out immediately after user logs in when client and server system clocks don't match

If the client system's clock is further ahead than the timeout specified, the GUI will immediately timeout after the user logs into the system.  

It is recommended that a time synchronization service, such as NTP be configured on the server and client.

ImageServer

8226

Media writer provides no progress during "Creating disc image" stage, which can take a very long time

This stage may take a long time, depending on the size of the images being written. Wait.

Workstation

8262

ImageServer Web GUI does not immediately show modified message after restarting a modified ImageServer shredhost

The anti-tampering mechanism in the ImageServer does not immediately display to the user when the installation has been modified.  It requires either the server to be rebooted or IIS to be restarted before the ImageServer shows that the installation has been modified.

ImageServer

8394

Key Image display sets with multiple study references always show a placeholder image for images from the "other" study

When you capture key images from more than one study in a session, all captured key images are added to a new KO series in all of the affected studies. It is arguable whether or not this is the correct way to do it, but the reason for doing it was to alert the user that key images were created in the same session for multiple studies regardless of which study was (later) opened.

However, when you open one or all of the affected studies (even via multi-selection), only key images from the study to which the key image display set belongs are shown; others are placeholder images.

Workstation

8458

Remnant orphaned SQL Database files cause the installer to fail

Sometimes when SQL Server goes to delete a database it leaves behind the underlying database files, e.g. mdf, ldf, and ndf files, even though the database had been deleted.  When this occurs, there are problems installing the ImageServer properly.  The workaround is to delete the database files through the SQL Management Studio

ImageServer

8819

Viewer will not print/export Fusion images

There is an issue with exporting and printing Fusion images - these operations may or may not complete successfully.

To workaround, toggle the colour bar overlay off before attempting to print or export. Alternatively, consider taking a screen capture.

Workstation

9252

Workstation does not properly support pixel padding value

No workaround. Images with pixel padding values may not display as the manufacturer of the modality intended.

Workstation

9449

The Easy Image Selection tool (Easel) can push the last study out of view when there are many related studies.

In Easel, if there are many related studies, it is possible that hovering over certain studies will "push" the last study out of view. When examining a list of studies in Easel, the user should use the scrollbar as a cue to whether there are more studies in the list.

Workstation

9660

Auto-refresh turns itself off on the Work Queue page

The Auto-refresh feature may turn itself off. Until this defect is addressed, the user can reset the auto-refresh or refresh manually.

ImageServer

9850

Unable to log in if timeout is less than SessionTokenCachingTimeToLiveSeconds

SessionTokenCachingTimeToLiveSeconds, by default 45 seconds, must remain less than the User Session timeout value, by default 15 minutes. If this is not the case, it users will be locked out of the system. The only way to recover is to modify the database directly and change the value back - which we do not recommend you do without contacting support

EnterpriseServer

9852

Searching for accented characters requires an exact match

For example searching for "López" will not find "Lopez" and vice versa. This is not technically a defect, but the likelihood of inconsistent data is high and it makes searching more difficult. The workaround is to use the ? wildcard when searching for these potentially different characters.

Workstation

9975

"My Computer" can perform poorly when accessing folder containing many zip files

No workaround.

Workstation

10703

WebPortal does not check if the browser has a PDF viewer plugin

If a browser does not have a PDF viewer plugin, the user is prompted by the browser to save or open the file ("Report.pdf"). If the user chooses to save the file, which may contain confidential patient information, it will remain on the computer until it is explicitly deleted.

Saved files should be managed as one would manage other PHI. Installing a PDF reader like Adobe Acrobat, will allow users to view PDF attachments and manage the deletion of the file after viewing.

WebPortal

11023

 "Unable to connect to the server. Refresh the page when your connection is restored." is misleading

When the MaxConnections for the Webstation has been exceeded (100 by default), the user gets this misleading message when the network connection is apparently ok and other webstations are still running properly.

It is possible to adjust the number of MaxConnections in the shredhost config.

Webstation

11333

Workstation GUI appears incorrectly when Windows is configured to use 125%

The workaround is to change the setting back to 100% (96 DPI)

Workstation

11375

Starting a procedure before its scheduled time causes scheduling conflicts for new procedures.

If a future scheduled procedure is checked-in, the scheduled start date/time is updated with the current timestamp but the scheduled end time is not changed. When a user attempts to create a new procedure that is within that extended time span between the new start time and the original end time, the modality appears "occupied", causing the conflict dialog to appear. This will not be obvious from the calendar.

The workaround is to reschedule future procedures before starting them.

RIS

11634

DICOM Editor is unusable for sufficiently large multiframe images

Workstation sometimes becomes unresponsive and crashes when opening a large multiframe image in the DICOM Editor.

Workstation

11639

Cannot copy a subset of frames in Enhanced MR/CT studies to the Clipboard

On an Enhanced CR or MR, Copy Range of Images to Clipboard does not allow user to select a range of images (frames)

Workaround: If copying individual frames is essential, consider having the modality resend the study using a non-Enhanced SOP class

Workstation

11658

Reference Lines on Enhanced CT/MR always show frame #1

Reference lines always say "1" (image number) on Enhanced CT/MR

Workstation, Webstation DX

11680

PDF reports not viewable on Surface IE

On Microsoft Surface’s Internet Explorer, PDF reports are not viewable

Webstation, Webstation DX

11686

Some tools in the Webstation may become unresponsive when user switches to another application using ALT-Tab

Similar to 11688.  Webstation thinks that a shortcut is being activated.

Workaround: Press ALT again, or use the mouse to switch applications instead to avoid the problem entirely.

Webstation, Webstation DX

11688

Using keyboard to change active browser window causes Webstation to think a shortcut is being used

Workaround: Press CTRL again, or use the mouse to switch applications instead to avoid the problem entirely.

Webstation, Webstation DX

11695

Reformatting a fusion display set results in a reformat of the underlying CT only

Reformatting of fused series are not currently supported.

Webstation, Webstation DX

11707

Incorrect study status shown on the GUI when server rules are being re-applied to the study

While server rules are being re-applied to a study (by running the Partition Re-apply Rules service), the study status on the Studies page changes to "Online-Idle" with "Idle" being a link which user can click on. Clicking on the link will open the Work Queue page but nothing is shown on the screen because there's no related WQI for the study.

ImageServer

11713

Webstation DX imagebox does not apply the state of overlays in Hanging Protocols

In the Workstation, the state of the overlay can be captured to a hanging protocol on a per imagebox basis. However, when the HP is applied in Webstation DX, the default overlays are applied for every imagebox.

Webstation DX

11732

Opening breast tomosynthesis images on the Portable Workstation is very slow and sluggish

Because of the size of the images, loading them from a CD is very slow.  Load time can be as much as 20 seconds per image.

Workstation, Portable Edition

11772

Webportal may crash if browser window is resized

If user resizes the browser window when images have been loaded, Silverlight may crash and user has to reload the WebPortal.  Only happens on Chrome.

Workarounds: Resize before opening studies, maximizing the window, or use a different browser

WebPortal

12555

ImageServer does not work properly when partition AE Title contains space characters

If the Partition AE Title contains a space character--which is allowed in DICOM--  streaming and the web viewer n the ImageServer will stop working.

Workaround: Do not use spaces in the Partition AE Title

ImageServer

12561

Uninstalling the ImageServer may affect other components

When the ImageServer is uninstalled, users may experience problems on other components such as the WebPortal.

Examples include:

  • Users of the WebPortal and ImageServer WebComponents (outside firewall) are not be able to open any studies.
  • If the user is configuring the IntergationServer and needs to query the ImageServer for the partition ID (in Admin > ImageServer? > Server Partitions menu), an error will be displayed in the Workstation.

Workaround: User must either reinstall the ImageServer, or modify the EnterpriseImageServerServiceSetting's BaseUrl to point to another valid ImageServer installation and restart services on all servers.

If the WebPortal is being used, the ClearCanvas.ImageViewer.Web.WebViewerServices setting in the WebPortal shredhost config must be updated manually to the hostname of the ImageServer.

ImageServer

12562

Cannot get Explorer back if you cancel out of closing Workstation

If you have unviewed layouts, close workstation but cancel out of the closing operation, Explorer will have been closed and you cannot get Explorer back.

Workstation

12567

Web Components Upgrade breaks manifest

When upgrading the Web Components installation over Rigel Web Components, the manifest will be broken. Clean installs of Web Components will be fine.

Workaround:  Uninstall/re-install, as suggested by the Getting Started Guide

Web Components